The third Advanced Graphite Creep (AGC-3) experiment was designed to irradiate various types of graphite specimens at a temperature of 900°C. The specimens were irradiated in an instrumented leadout capsule experiment in the east flux trap of the ATR during cycles 152B, 154B, 155A, and 155B. Temperature was monitored using twelve thermocouples located at various elevations in the reactor core, and a helium-argon gas mixture was used for gas gap temperature control of the specimens. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and helium-argon gas flows, and as-run calculations of heating rates and displacement per atom (DPA) in graphite. The accuracy of the model is assessed by comparing measured and calculated thermocouple temperatures. Uncertainty in gas gaps may preclude an accurate temperature calculation. In these cases, adjustments are made to the thermal model in order to reconcile the measured and calculated thermocouple temperature and to ensure the accuracy of the calculated specimen temperature.