A Two-Cycle Automated Approach to Electrical Resistivity Measurement of SiC Monitors for Peak Irradiation Temperature
An experimental system was designed and optimized to acquire real-time electrical resistance of the monitors during annealing. The system was then used to anneal irradiated silicon carbide (SiC) monitors. The altered resistance of the SiC monitors between the first heating cycle and the mean of the heating and cooling cycles that followed was found to […]