ViBRANT Applied as a Closed Loop Flux and Thermal Surrogate
Surrogate testing platforms provide a means to develop a target aspect of a larger system. Some systems target single aspects while others are more wholistic. ViBRANT (Visual Benign Reactor as Analog for Nuclear Testing) aims to be a wholistic system by representing the primary reactor behaviors through an accessible LED driven reactor core, photodiodes, thermocouples, […]
Irradiation Results of Commercial Neutron and Gamma Sensors at the Ohio State University Research Reactor
This report serves to present the evaluation results of commercial radiation detectors (SPNDs) with the potential to accomplish the data objectives—having sufficient gamma and fast neutron sensitivity—at temperatures near 650°C. The detectors chosen for evaluation are gamma ion chambers from Exosens (previously known as Photonis) models CRGA11 and CRGE32 and tantalum-based self-powered neutron detectors (Ta […]
Demonstration of Temperature Compensation Techniques for SPNDs Operating in High Temperatures
This report presents the testing results of rhodium-based self-powered neutron detectors (Rh-SPND) irradiated in a furnace dry tube from ambient temperature to 850°C at the Ohio State University Research Reactor. The purpose of the experiment is to demonstrate the technique and application of a temperature compensation technique for the Rh-SPND. This is performed by characterizing […]
Irradiation Testing of Nuclear Flux Sensors – Presentation for 2021 ASI Annual Webinar
This power point presentation is a summary of the work produced in FY2021 under the Irradiation Testing of Neutron Flux Sensors project funded by DOE’s Advanced Sensor Initiative, and the outlook for FY22. The objective of this portion of the ASI program is to “Test and demonstrate in-pile instrumentation in conditions similar to those expected […]
Development of Temperature Compensation Tools for SPNDs Operating in High Temperature Environments
Two rhodium-based self-powered neutron detectors (Rh-SPNDs) were irradiated at the Massachusetts Institute of Technology Reactor as a follow-on experiment to the heated irradiation previously conducted at the Neutron Radiography facility at Idaho National Laboratory. The experiment was conducted over the temperature ranges of 600-850°C to further examine the effects of temperature on the Rh-SPNDs. Four […]
Real Time In-Core Instrumentation: From Fuel and Materials Irradiation tests to Advanced Reactor Demonstration -Flux Sensors
Real Time In-Core Instrumentation: From Fuel and Materials Irradiation tests to Advanced Reactor Demonstration -Flux Sensors Project Summary