PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673 and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the SAM-2 irradiation which was conducted in position B8 of the ATR. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and sent to INL for loading into the SAM-2 assembly prior to irradiation. The SAM-2 experiment has 8 capsules labelled A through H designed for different exposures in successive irradiation cycles. This report is for the first three capsules, A, B and C, co-irradiated for 1 cycle. The remaining capsules and fluence monitors will be removed and analyzed after additional irradiation. Following irradiation, the fluence monitors from capsules A, B, and C were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.