With the recent need to qualify new reactor designs such as the Versatile Test Reactor (VTR), fuel performance calculations need to be performed to determine safety criteria of the proposed designs. In order to validate the fuel performance results obtained by a fuel performance code, BISON, for new reactor designs, legacy fuel from EBR-II and FFTF MFF with Post -Irradiation Examination (PIE) data need to be used as validation cases to benchmark models. In this work, BISON has been paired with the Fuels Irradiation & Physics Database (FIPD) and IFR Materials Information System (IMIS) to supply PIE data for comparison with simulations of EBR-II experiments X447/X447A. X447/X447A were assessed by implementing models for Fuel Cladding Chemical Interaction (FCCI) within BISON and optimizing the friction coefficient between the fuel surface and the cladding, the anisotropic swelling factor, and the HT9 first thermal creep scalar (which scales the first term in the HT9 creep equation) to best match the PIE axial fuel swelling height and cladding profilometry for all pins in X447/X447A. The optimal values were found using a generic algorithm developed to select different values for the three parameters until end criteria was met and error couldn’t be reduced further. The BISON-simulated cladding profilometry was evaluated using Standard Error of the Estimate (SEE) to account for the profile shape of the cladding profilometry. Optimal values for the friction coefficient, anisotropic fuel swelling factor, and HT9 first thermal creep scalar were found to best fit the BISON simulation results to the PIE measurements found in IMIS and FIPD. Improvements to current models are suggested to account for the underprediction of fuel swelling at low burnups and the overprediction of fuel swelling at higher burnups observed for the axial fuel swelling height. Although two pins in EBR-II X447/X447A (DP70 and DP75) were known to fail due to FCCI, none of the pins simulated in BISON reached a cumulative damage fraction (CDF) above 0.008 with FCCI correlations coupled in the BISON simulations. The error estimate generated for all pins in X447/X447A using optimal values was 209 µm, which is deemed acceptable.